PART X FALL PROTECTION — Temporary flooring
146
Temporary flooring that is constructed or installed in accordance with section 141 shall
146(a)
be constructed or installed at each floor level of the work area where work is in progress;
146(b)
extend over the whole work area except for openings necessary for the carrying out of work;
146(c)
be able to withstand 4 times the maximum load likely to be imposed on it; and
146(d)
be securely fastened to and supported on members that are able to withstand 4 times the maximum load likely to be imposed on them.