PART XIV CRANES, HOISTS AND OTHER LIFTING EQUIPMENT — Structural inspection
342
(1) Before erection of a tower crane, the structural components of the crane shall be
342(a)
inspected to determine their integrity by a qualified person using non-destructive testing (NDT) methods meeting the requirements of the Canadian General Standards Board (CGSB); and its structural components shall be inspected to determine their integrity by a qualified person using NDT methods meeting the requirements of the CGSB; and
342(b)
repaired where necessary and those repairs certified by a professional engineer as safe for use. after the inspection required by paragraph (a), the crane, including necessary repairs, shall be certified by a professional engineer as safe for use.
342(2)
Where a tower crane remains erected at a workplace for more than 12 months
342(3)
The inspection and certification of a tower crane scheduled to be dismantled within 15 months of erection may be delayed until before the next erection of the crane.
Not legal advice. Verify the cited article against the signed agreement.